Problem solving technique in ocular prosthetic reconstruction

 

M. El-Dakkak, BChD, HDD, MS
Department of Prosthetic Dental Sciences, King Saud University, College of Dentistry, P.O. Box 60169, Riyadh 11545, Saudi Arabia

 

This study was conducted on twelve subjects; who had undergone surgical enucleation of the eye as a result of accidents. Their cosmetic problem was corrected by serial construction of cone formers with bigger sizes and lining modification of stock eye prostheses. The method resulted in sufficient room for the retention of the eye prosthesis and gradually improved the cosmetic problem developed from narrow palpebral fissures.

 

Saudi Dental Journal 1990;2(1):7-10. 

 