|
The Effect Of Different Protective Coatings On The Surface
Hardness Of Glass Ionomer Cements
Laila A. Saleh, DDS, MSD, Moustafa F. Khaiil, BDS, MS, PhD
College of Dentistry, King Saud University, P.O. Box 60169, Riyadh 11545, Saudi Arabia.
Class ionomer cements are liable to hydration and dehydration
during their initial set. The use of a light-activated bonding resin is
advocated as a protective method of limiting water movement across the surface.
This study tested the effect of five coating materials on the surface hardness
of Ketac-Fil restorative glass ionomer. Cocoa butter (CB), Ketac varnish (KV),
clear finger nail polish (NP), copalite varnish (CV), and a light-cured
unfilled resin (UFR) were evaluated. The surface hardness of each group was
determined at 1 hour, 24 hours and 1 week, and compared to that of unprotected
surface as a control (C). The results showed none of the tested coatings was
able to maintain the original surface hardness of the unprotected cement. CB,
KV and NP were less effective in reducing the surface hardness of Ketac-Fil
than CV and UFR.
The glass ionomer cement (GIC) was introduced to the
dental profession by Wilson and Kent in 1972.1 Today the GICs have a wide range of
clinical applications.2 They may be used as
restorative materials for class III and class V cavities, fissure sealants,
luting agents for cast restorations, restoration of deciduous teeth, lining
materials, core build up, restoring minimal cavity preparations such as tunnel
preparation, and dentin substitute in laminate restorations. These types of
cements combine certain favorable characteristics of the silicate and the
polycarboxylate cements.3,4 Glass ionomer cements
have porcelain-like translucency,5 release
fluorides over a period of time6'7 and adhere
to tooth structure and base metals.8,9 In
recent years, GICs have shown a promise as bone cements since they are
bioactive and promote bone growth.5
The glass ionomer cement is composed of fluoride
containing acid decomposable, calcium-alumino-silicate glass powder, and
polyacrylic acid or alkenoic acid. The reaction between the powder and the
liquid is an acid-base reaction. On mixing, the glass powder reacts with the
acid; calcium and aluminum ions are displaced from the glass in the form of Ca2+ and Al3+ along with the fluoride ion F~. The Ca2+ ions react rapidly in the liquid forming a
salt bridge between the negatively charged carboxylic groups. The
polycarboxylate chains become cross-linked by this process and soon form a gel
which marks the initial setting of the cement. The Al3+ ions react more slowly largely because they
are trivalent and have more difficulty in forming the salt bridge. However,
they slowly increase the cross-linking and produce further hardening until the
final setting is achieved.10
Despite all improvements of the new glass ionomer cements
over the early ones, they still suffer from the effect of moisture
contamination and desiccation during the reaction stages. After setting and
before the cement is completely hardened, the calcium and aluminum salts are in
the soluble form and can be permanently lost if they come in contact with
water, resulting in a weak cement with a rough and opaque surface.11-12 Desiccation,
on the other hand, retards the reaction due to the loss of water. In such a
case, the material undergoes shrinkage with crazing of the surface.13 The susceptibility to desiccation decreases as
the cement matures but continues from one to thirty days depending on the brand
of cement. Accordingly, the cement must be protected against moisture gain or
desiccation 10- 30 minutes after insertion.14 The ideal protective film against these two
extremes is yet to be developed. Some manufacturers provide the profession with
special coating varnishes.15 It has been found that
GIC liners and bases showed a significant reduction in surface hardness when a
cavity varnish was applied.16 It was
also found that Ketac Fil showed a significantly rapid development of surface
hardness than did some other brands.17
The purpose of this study was to compare the effect of
different protective coatings on the surface microhardness of Ketac-Fil glass
ionomer cement.
The materials used for this study were Ketac-Fil* glass
ionomer restorative and five coating materials. Eighteen fillings were prepared
in resin blocks. Cylindrical blocks of self-curing acrylic resin** were
prepared using copper molds 15 mm long and 12 mm in diameter. Each cylinder was
placed on a glass slab, filled with the resin and covered with a glass slide to
obtain a smooth and flat surface when the resin is hardened. On the top surface
of each block, a cavity was prepared. The cavities were 5 mm in diameter and
about 3 mm deep as shown in Fig. 1. The cavities were filled with the glass
ionomer cement using the manufacturer's recommended technique. Immediately
after insertion of the filling, the surface of the restoration was covered by a
Mylar matrix and pressed with a microscope slide to obtain a smooth and flat
surface. Five minutes later, the glass slide and matrix were removed and the
surface was immediately covered by the protective coating.
The eighteen blocks were divided into six groups, each
consisting of the three specimens; five treatment groups, based on the material
used as a protective coating, and one control group. In the control group, the
surface was not coated.
Each of the five experimental groups were coated with
either cocoa butter
(CB), Ketac varnish* (KV), clear
finger nail polish (NP), copalite varnish** (CV), or light-cured unfilled
resin*** (UFR). The specimens were then stored in an environmental chamber at
37°C and 80% relative humidity until they were ready for testing.
The surface hardness (average of three measurements) for
each specimen was measured after one hour, 24 hours, and one week using a
Viker's microhardness tester.**** All indentations were made at a load of 100 g
for 5 seconds.
Statistical Analysis
The experiment has been performed like a split plot design18 where the groups were considered as the whole
unit treatment and the time as the sub-unit treatment. Analysis of variance
(ANOVA) has been used to compare the time factors as well as the treatments. To
test the validity of the repetition of the same sample, repetition factor was
also included in the ANOVA. The least significant difference (LSD) was
calculated to compare group means, time means, time means within the same
group, and group means within the same and/or different times.
The mean values of the surface hardness obtained with
different coating materials and time intervals are presented in Fig. 2 and
tabulated in Table 1. Analysis of variance (ANOVA) is presented in Table 2. The
LSD for all treatments at all times is presented in Table 3.
The general pattern was the increase in surface hardness
with time for all surface treatments as well as for the control (Table 1).
Coating the surface with unfilled resin resulted in a great reduction in
surface hardness at all times. The surface hardness with the unfilled resin was
at least 50% less than that with the rest of coatings except with Copalite
varnish at 24 hours. The control group, on the other hand, gave the highest
value of surface hardness. Analysis of variance (Table 2) revealed that there
was at least one coating material that is significantly different (P < .001)
from the other four, at least one time interval was significantly different (P
< .001) from the other two, and at least one coating material showed a significant
difference (P < 0.05) at each time interval. The least significant
difference (Table 3) showed the differences in surface hardness among groups as
a whole and at different time intervals.
Specimens treated with cocoa butter, Ketac varnish and
nail polish were comparable since they showed no significant difference in
surface hardness at the one hour and one week periods. However, hardness of
specimens treated with KV was about 16% lower than these two treatments after
24 hours. Values obtained with Copalite varnish, although much higher than
those obtained with the unfilled resin, were significantly lower than those
obtained with other surface treatments, especially after 24 hours.
The surface hardness may be defined as the resistance of a
material surface to abrasion.,q This
definition makes the surface hardness an important parameter in evaluating
dental materials, especially restorative materials. Considering glass ionomer
cements and similar materials commonly used in class V restorations, they are
susceptible to abrasion caused, at least, by everyday use of the toothbrush. It
has always been recommended that glass ionomer cements must be covered
immediately after setting with a water-proof coating. It was demonstrated by
O'Hara16 that glass ionomer liner and base may suffer a
reduced surface hardness if put against cavity varnish. Although not
substantiated by a scientific explanation, the finding was a warning that other
coating materials may behave similarly. Earl et al20 have shown
that immediate covering of immature glass ionomer cement with a light-cured
bonding resin is the most effective method of limiting water movement across
the surface. Hotta et al21 have
studied the effect of different coating materials on the color stability of
glass ionomer cement. They came up with the conclusion that coating with
light-cured resin is the best in this regard. However, the effect of these
recommended coating materials on the surface hardness of the restorative glass
ionomer cement has not been reported in the Iiterature. It was surprising that
in the present study, all protective coatings used have resulted in a reduction
of the surface hardness of the cement when compared with the control. It was
also interesting that the light-cured unfilled resin caused the maximum drop in
surface hardness. The Copalite varnish was better than the resin in this
respect, yet it gave a low value of surface hardness at the 1 hour and 24 hours
compared to one week hardness. After one week, the surface hardness of the
resin coated cement was less than the one hour hardness of all other coating
materials. Cocoa butter, Ketac varnish and nail polish were all comparable in
reducing surface hardness and their effect was less than that of the Copalite
varnish and the unfilled resin.
None of the protective coatings used in this study was
able to maintain the original surface hardness of the unprotected glass ionomer
restorative. Cocoa butter, Ketac varnish and nail polish were the least
effective in reducing the surface hardness of Ketac-Fil compared to Copalite
varnish and unfilled light-cured resin.
The authors are grateful to Dr. Nazeer Khan,
Biostatistician, Research Center, College
of Dentistry at King
Saud University,
for his valuable work in the statistical analysis of data and to Professor H.
Mohammed-Al Tahawr, Chairman of the Department of Prosthetic Dental Sciences, College of Dentistry,
King Saud University
for his advice and encouragement relative to the experiment.
- Wilson AD, Kent
BE. A new translucent cement for dentistry. The glass ionomer cement. Br Dent J
1972;132:133-35.
-
Wilson AD. Developments in glass ionomer cement. Int J Prosthodont
1989;2:438-46.
-
Kent BE, Lewis BG, Wilson
AD. The properties of a glass ionomer cement. Br Dent J 1973;135:322-26.
-
Saito S. Characteristics of glass ionomer and its clinical
applications. Relation between hardening reaction and water. Int J Dent Mat
1978;8:1-16.
- Wilson AD, McLean JW.
Glass ionomer cement. Chicago, II: Quintessence Publ Co
!nc, 1988:13-4.
-
Relief DH, Bradley EL, Denton JC, Switzer P. Enamel and
cementum fluoride uptake from a glass ionomer cement. Caries Res
1984;18(3):250-57.
-
Valk JWP, Davidson CL, The relevance of controlled
fluoride release with bonded orthodontic appliances. J Dent 1987;15:257-60.
-
Maldonado A, Swartz ML, Phillips RW. An in vitro study of
certain properties of a glass ionomer cement. J Am Dent Assoc 1978;96:785-91.
-
Hotz P, McLean JW, Seed I, Wilson AD. The bonding of glass
ionomer cements to metal and tooth substrates. Br Dent J 1977;142:41-7.
-
Williams DF, Cunningham J. Materials in clinical
dentistry. Oxford University Press, 1979:154-58.
-
Mount GJ, Makinson OF. Glass ionomer restorative cements:
Clinical implications of the setting reaction. Oper Dent 1982;7:134-41.
-
Causton BE. The physico-mechanical consequences of
exposing glass ionomer cements to water during setting. Biomat 1981;2:112-15.
-
Wilson AD, McLean JW. Glass ionomer cement. Quintessence
Publ Co Inc, 1988:51.
-
Phillips S, Bishop BM. An in vitro study of the effect of
moisture on glass ionomer cement. Quintessence Int 1985;16:175-77.
-
Wilson AD, Paddon JM, Crisp S. The hydration of dental
cements. J Dent Res 1979; 58:1065-71.
-
O'Hara JW, Lentz DL, Taylor TJ. Surface characteristics of
glass ionomer cement when treated with cavity varnish. Oper Dent 1989;3:133-35.
-
Brackett WW, Johnston WM. Relative microhardness of glass
ionomer cement as an indicator of finishing time. J Am Dent Assoc
1989;118(5):599-602.
-
Steel RGD, Torrie |H. Principles and procedures of
statistics, a biometrical approach. 2nd ed. New York:McGraw-Hill, 1980:377-400.
-
Philips RW. Skinner's science of dental materials. 9th ed.
Philadelphia:WB Saunders Co, 1991:3-42.
-
Earl MSA, Mount GJ, Hume WR. The effect of varnishes and
other surface treatments on water movement across the glass ionomer cement
surface. Aust Dent J 1989; 34(4):326-29.
-
Hotta M, Hirukawa
H, Yamamoto K. Effect of coating materials on restorative glass ionomer cement
surface. Oper Dent 1992;17:57-61.
|